Datasheet explanation
Items in the datasheet are explained below. Please refer to the corresponding
number in columns.
DATASHEET with Instructions
| Wastewater treatment facility identification |
Facility name |
(1) |
| Facility location |
(2) |
| Facility overview |
Operating period |
(3) |
| Wastewater characteristics |
(4) |
| Treatment process |
(5) |
| Process flow diagram |
(6) |
| Specification of reactors & primal equipment |
(7) |
| Facility Operation status |
Daily amount of treated wastewater |
| Actual |
(8) m³/day |
Design |
(9) m³/day |
|
| Annual electric consumption |
| Actual |
(10) kWh |
Design |
(11) kWh |
|
| Annual amount of sludge generation |
| Actual |
(12) DSt |
Design |
(13) DSt |
|
Process performance
(Influent & effluent water quality) |
Design |
| |
Influent quality
(14) |
Effluent quality
(15) |
Performance (16) |
| SS |
mg/L |
mg/L |
|
| BOD |
mg/L |
mg/L |
|
| COD (Cr, Mn) |
mg/L |
mg/L |
|
| T-N |
mg/L |
mg/L |
|
| T-P |
mg/L |
mg/L |
|
| Coliform group |
|
|
|
| Fecal coliforms |
|
|
|
| E. coli bacteria |
|
|
|
| Other |
|
|
|
|
| Actual |
| |
Influent quality
(17) |
Effluent quality
(18) |
Performance
(19) |
| SS |
mg/L |
mg/L |
|
| BOD |
mg/L |
mg/L |
|
| COD
(Cr, Mn) |
mg/L |
mg/L |
|
| T-N |
mg/L |
mg/L |
|
| T-P |
mg/L |
mg/L |
|
| Coliform
group |
|
|
|
| Fecal
coliforms |
|
|
|
| E.
coli bacteria |
|
|
|
| Other |
|
|
|
|
| Operation & maintenance |
Annual Chemical consumption |
(20) |
| O & M personel |
(21) |
| Remarks |
(22) |
| Other |
Capital |
(23) |
| Facility management body Contact information |
(24) |
| Manufacture/ designer |
(25) |
| Information source |
(26) |
Datasheet entry items: explanation and examples
< Wastewater treatment facility identification >
| (1) |
Facility name : Name and the type of facilities |
| |
(example) A city’s wastewater
treatment plant |
| (2) |
Facility location: Name of city, town and province |
| |
(example) A town, B province |
< Facility overview >
| (3) |
Operating period: Startup month and year if the facility is now
in operation. |
| |
(example) 4 years (since April, 2001) |
| |
(example) 7 years (1988 ~ 1995) |
| (4) |
Wastewater characteristics:
 |
| |
• Domestic wastewater |
| |
(example) household wastewater, night
soil |
| |
• Industrial wastewater |
| |
(example) wastewater from dye factory,
from food processing factory |
| |
• Ambient water |
| |
(example) Lake, pond, river, canals |
| (5) |
Treatment process: Common name of treatment process. If the treatment process is new and less common, its characteristics and mechanism is summarized in remarks.
 |
| |
(example 1) Conventional activated sludge process |
| |
(example 2 ) Chemical precipitation and sand filtration |
| (6) |
Process flow diagram: Show the flow diagram as well as sketch, and photographs. |
| |
(example)
|
| (7) |
Specification of reactors/ equipment: Specification (volume, dimensions) of reactors/ tanks, and main equipment |
| |
(example) Surface loading rate: ** m³/m²/day. Retention time: **hr.
(example) Oxidation pong: ** m³. Facultative pond: **m³. Sedimentation pond: ** m³.
(example) Oxidation ditch: length 30m, width 5m, depth 2m.
|
< Facility operation status >
Daily amount of treated wastewater: [m³/day]
| (8) |
Actual: Annual average daily flow. Comment in case of daily maximum or seasonal trend. |
| |
(example) 200 m³/day (maximum daily flow. 300 m³/day) |
| (9) |
Designed: Same as the actual. |
Annual electric consumption: [kWh] Specify the period of time.
| (10) |
Actual: |
| |
(example) 3,600 kWh
(example) 4,200 kWh (monthly) |
| (11) |
Designed: Same as the actual. |
Annual amount of sludge generation:
[DSt]
Specify with the dry solid base.
| (12) |
Actual: Annual average daily flow. Comment in case of daily maximum or seasonal trend. |
| |
(example) 6,000 DSt
The data provided with the volume base can be converted to the weight base as shown below.
(calculationexample)
• data: 300,000 m³/year (water content 98%)
• density: approximate 1,000 kg/ m³
• dry solid: 300,000 m³ × 1,000 kg/m³ × (100-98)/100 = 6,000,000 kg
(= 6,000 DSt )
|
| (13) |
Designed: Same as the actual. |
< Water Quality >
Process performance (Influent & effluent water quality):
- Enter all water quality items which are required to remove in accordance with the effluent standard.
- In addition to SS, BOD, COD, T-N, T-P and coliforms, enter other quality items if available.
- Indicate the specific method if used for the water quality tests.
- For COD, please circle the method of Cr or Mn.
(example) COD (Cr, Mn) (Potassium dichromate method)
(example) COD (Cr, Mn) (Potassium dichromate method)
Designed
| (14) |
Inlet quality: Designed inlet wastewater quality |
| (15) |
Effluent quality: Designed effluent quality based on the standard. |
| |
(example) CODCr < 50 mg/L |
| (16) |
Performance: Designed removal ratio |
| |
(example) BOD removal rate over 90% |
Actual
| (17) |
Inlet quality: Explain the time period of average calculation; daily, monthly, or annually. |
| (18) |
Effluent quality: Same as the designed. |
| |
(example) SS 10mg/L (average of FY2003) |
| (19) |
Performance: Calculate the removal ratio using the inlet and effluent water qualities, if both data are avilable. |
< Operation & Maintenance >
| (20) |
Chemical consumption: Annual amount of chemical compounds such as coagulants, using for the wastewater and sludge treatment. |
| |
(example) Coagulant PAC 36 ton/ year (Injection ratio: x[mg/L]) |
| (21) |
O & M personnel: Enter the number of O&M persons. |
| |
(example) 2 resident operator.
(example) Automatic operation and monitored by 1 patroller twice a week.
|
| (22) |
Remarks: Provide useful information such as facility establishment background, circumstances of surrounding waters of the treatment facility, and son on.
|
| |
(example) To comply with Wastewater quality standards and to conserve the water quality of public water bodies. |
< Other >
| (23) |
Capital cost: Add the explanation of the counted items. |
| |
(example) 60 million JPY, including only machinery and equipment.
(example) 30 million USD, during construction in the middle of 80s. |
| (24) |
Facility management body: Enter their homepage address if available. |
| |
(example) Environmental Planning Bureau, City of Yokohama
http://www.city.yokohama.jp/me/kankyou/gesui/index.html |
| (25) |
Manufacture/ designer: Indicate the homepage address of the manufacture/ designer.
|
| (26) |
Information source: Name of datasheet information provider. |
|